Installation Manual
TLA 700 Series
Logic Analyzer
070-9774-02
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
Vista de página 0
1 2 3 4 5 6 ... 81 82

Resumo do Conteúdo

Página 1 - 070-9774-02

Installation ManualTLA 700 SeriesLogic Analyzer070-9774-02WarningThe servicing instructions are for use by qualifiedpersonnel only. To avoid personal

Página 2

General Safety Summary viTLA 700 Series Installation ManualTerms in this Manual. These terms may appear in this manual:WARNING. Warning statements ide

Página 3 - TEKTRONIX SERVICE OPTIONS

TLA 700 Series Installation Manual viiService Safety SummaryOnly qualified personnel should perform service procedures. Read this ServiceSafety Summar

Página 4

Service Safety viiiTLA 700 Series Installation Manual

Página 5 - Table of Contents

TLA 700 Series Installation ManualixPrefaceThe TLA 700 Series Installation Manual is intended to help you install yourTLA 700 Series Logic Analyzer.

Página 6 - List of Figures

PrefacexTLA 700 Series Installation ManualRelated DocumentationIn addition to this installation manual, the following documentation is availablefor yo

Página 7 - List of Tables

PrefaceTLA 700 Series Installation ManualxiService OfferingsTektronix provides service to cover repair under warranty as well as otherservices that ar

Página 8

PrefacexiiTLA 700 Series Installation ManualSelf Service. Tektronix supports repair to the replaceable-part level by providingfor circuit board exchan

Página 9 - General Safety Summary

TLA 700 Series Installation Manual1Basic InstallationThis chapter describes all of the steps needed to install the TLA 700 Series LogicAnalyzer. It is

Página 10 - Symbols and Terms

Basic Installation2TLA 700 Series Installation ManualCheck the Environmental RequirementsRead this section before attempting any installation procedur

Página 11 - Service Safety Summary

Basic InstallationTLA 700 Series Installation Manual3Table 1 lists the operating requirements for the logic analyzers. Refer to theTLA 700 Series Logi

Página 12 - Service Safety

Copyright  Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers andare protected by United States

Página 13

Basic Installation4TLA 700 Series Installation ManualFigure 1 shows chassis ground connections. Use the chassis ground connectionsto connect the groun

Página 14 - Related Documentation

Basic InstallationTLA 700 Series Installation Manual5Install the ModulesCAUTION. Do not install or remove any modules while the mainframe is poweredon

Página 15 - Service Offerings

Basic Installation6TLA 700 Series Installation ManualCover Empty SlotsIf you have any unused (empty) slots in your mainframe, you must install blanksl

Página 16 - Contacting Tektronix

Basic InstallationTLA 700 Series Installation Manual7Connect the Standard and Other AccessoriesThe accessory connections are the same as those you wou

Página 17 - Basic Installation

Basic Installation8TLA 700 Series Installation ManualTable 2: Additional accessory connection information Item DescriptionMonitor If you use a non-sta

Página 18 - Benchtop Mainframe

Basic InstallationTLA 700 Series Installation Manual9Connect the ProbesConnect the logic analyzer probes and the optional retaining brackets as showni

Página 19 - Operating Requirements

Basic Installation10TLA 700 Series Installation ManualPower On the Logic AnalyzerFollow these steps to power on the logic analyzer for the first time.

Página 20 - Connections

Basic InstallationTLA 700 Series Installation Manual112. Connect the power cord.CAUTION. Although the benchtop mainframe can use the power cord with t

Página 21 - Install the Modules

Basic Installation12TLA 700 Series Installation ManualPowering Off the Logic AnalyzerThe portable mainframe has a built-in soft power-off function tha

Página 22 - Cover Empty Slots

Basic InstallationTLA 700 Series Installation Manual13Connect the oscilloscope probes to the Probe Compensation connector on thefront panel of the DSO

Página 23

TEKTRONIX SERVICE OPTIONSTektronix offers the following service options. These options are modular, flexible, and easy to order with your instru-ment.

Página 24

Basic Installation14TLA 700 Series Installation Manual

Página 25 - Connect the Probes

TLA 700 Series Installation Manual15Installing Microprocessor Support SoftwareEach microprocessor support package comes with setup software and requir

Página 26 - Power On the Logic Analyzer

Installing Microprocessor Support Software16TLA 700 Series Installation Manual

Página 27

TLA 700 Series Installation Manual17The Next StepNow that you have set up your logic analyzer, you are ready to learn how to usethe logic analyzer for

Página 28 - (Optional)

The Next Step18TLA 700 Series Installation Manual

Página 29 - Back Up User Files

TLA 700 Series Installation Manual19In Case of ProblemsThis chapter provides information that addresses problems that you mayencounter while installin

Página 30

In Case of Problems20TLA 700 Series Installation ManualSoftware ProblemsYour TLA 700 Series Logic Analyzer comes with most software alreadyinstalled.

Página 31

In Case of ProblemsTLA 700 Series Installation Manual21CAUTION. Do not attempt to remove or reinstall modules in the logic analyzerwhile the logic ana

Página 32

In Case of Problems22TLA 700 Series Installation ManualTable 4: Troubleshooting (Cont.)Symptom Possible causes and recommended actionMainframe does no

Página 33 - The Next Step

In Case of ProblemsTLA 700 Series Installation Manual23TLA 700 Startup SequenceThe following information is intended to provide troubleshooting hints

Página 35 - In Case of Problems

In Case of Problems24TLA 700 Series Installation ManualPower onMainframe kernel testPass/Fail ?Module 1kernel testPass/FailModule 2kernel testPass/Fai

Página 36 - Hardware Problems

In Case of ProblemsTLA 700 Series Installation Manual25 Replacing Podlets on the P6417 Logic Analyzer ProbeAlthough your logic analyzer was fully test

Página 37

In Case of Problems26TLA 700 Series Installation ManualThe podlet replacement procedure consists of identifying the faulty podlet andreplacing it with

Página 38

In Case of ProblemsTLA 700 Series Installation Manual273. Using the screwdriver with the #1 Phillips tip, remove the four screws on theprobe housing o

Página 39 - TLA 700 Startup Sequence

In Case of Problems28TLA 700 Series Installation Manual5. Remove the remaining top and bottom probe housings and set them aside.Do not mix the probe c

Página 40

In Case of ProblemsTLA 700 Series Installation Manual2911. Refer to Figure 12 and bend the rubber comb to remove the faulty podletcable from the comb.

Página 41 - Moving Probe Podlets

In Case of Problems30TLA 700 Series Installation Manual14. Remove the faulty podlet cable from the podlet holder and replace it with thenew cable as s

Página 42 - Replacing Probe Podlets

In Case of ProblemsTLA 700 Series Installation Manual31Install color-coded ring onthe replacement cable andslide the ring down the tool.Installation t

Página 43

In Case of Problems32TLA 700 Series Installation Manual20. Insert the new podlet cable partially into the cable header housing. Place anew retaining s

Página 44 - Podlet cable

TLA 700 Series Installation Manual33Appendix A: Merging Logic Analyzer ModulesThis appendix describes how to merge two logic analyzer modules to form

Página 45 - Cut above color-coded ring

TLA 700 Series Installation ManualiTable of ContentsGeneral Safety Summary v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Se

Página 46 - Align the ground connectors

Appendix A: Merging Logic Analyzer Modules34TLA 700 Series Installation Manual4. Use the screwdriver with the T-10 Torx tip and remove the eight screw

Página 47

Appendix A: Merging Logic Analyzer ModulesTLA 700 Series Installation Manual359. Replace the cover while feeding the Merge cable through the hole in t

Página 48

Appendix A: Merging Logic Analyzer Modules36TLA 700 Series Installation Manual12. Push forward on the cover so the tab on the front edge of the cover

Página 49 - Merge Procedure

Appendix A: Merging Logic Analyzer ModulesTLA 700 Series Installation Manual3717. Check and tighten all screws to 4 in lbs.18. Place the Master module

Página 50

Appendix A: Merging Logic Analyzer Modules38TLA 700 Series Installation Manual3. Verify that the modules are fully seated before powering on the logic

Página 51 - Merge cable bracket

Appendix A: Merging Logic Analyzer ModulesTLA 700 Series Installation Manual39Merge cableFigure 20: Dressing the Merge cable before installing the cov

Página 52 - Make sure tab inserts into

Appendix A: Merging Logic Analyzer Modules40TLA 700 Series Installation Manual

Página 53 - Guide pins

TLA 700 Series Installation Manual41Appendix B: UpgradesThis appendix describes procedures for upgrading your logic analyzer softwareor firmware. The

Página 54 - Storing the Merge Cable

Appendix B: Upgrades42TLA 700 Series Installation ManualYou can update or reinstall the TLA 700 software by executing the setup.exeprogram on the Disk

Página 55

Appendix B: UpgradesTLA 700 Series Installation Manual43Installing TPIUse these procedures to install the TLA 700 Programmatic Interface (TPI). Inthes

Página 56

Table of ContentsiiTLA 700 Series Installation ManualList of FiguresFigure 1: Location of ground connections 4. . . . . . . . . . . . . . . . . . . .

Página 57 - Appendix B: Upgrades

Appendix B: Upgrades44TLA 700 Series Installation ManualNOTE. If you have difficulty configuring the network setup, contact your systemadministrator.2

Página 58 - Software

Appendix B: UpgradesTLA 700 Series Installation Manual457. Restart the logic analyzer, using the procedure in step 4.8. Start the TLA 700 application

Página 59 - Installing TPI

Appendix B: Upgrades46TLA 700 Series Installation ManualSetting Up Share-level Access for Microsoft Windows 95.To set up share-levelaccess for a clien

Página 60

Appendix B: UpgradesTLA 700 Series Installation Manual47Setting Up User-level Access for Microsoft Windows 95. To set up user-level accessfor a client

Página 61 - Microsoft Windows 95

Appendix B: Upgrades48TLA 700 Series Installation ManualAfter you set up the logic analyzer, you must set up the client machine using thefollowing pro

Página 62

Appendix B: UpgradesTLA 700 Series Installation Manual49If the client application requires use of the type library, you can generate it onyour platfor

Página 63

Appendix B: Upgrades50TLA 700 Series Installation ManualUpdating Module FirmwarePerform the following steps if you need to update or reinstall the fla

Página 64 - Microsoft Windows NT

Appendix B: UpgradesTLA 700 Series Installation Manual517. Reinstall the modules in the logic analyzer.8. Reconnect the power cord and power on the lo

Página 65 - Other Platform

Appendix B: Upgrades52TLA 700 Series Installation Manual20. Remove the module from the logic analyzer and remove the jumper from theFlash programming

Página 66 - Updating Module Firmware

Appendix B: UpgradesTLA 700 Series Installation Manual53Table 6: Controller BIOS setups for the TLA 700 application Parameter Factory setting Submenu

Página 67

Table of ContentsTLA 700 Series Installation ManualiiiList of TablesTable 1: Mainframe operating requirements 3. . . . . . . . . . . . . . . . . . . .

Página 68 - Controller BIOS Setup

Appendix B: Upgrades54TLA 700 Series Installation ManualTable 6: Controller BIOS setups for the TLA 700 application (Cont.)Parameter Factory settingSu

Página 69

Appendix B: UpgradesTLA 700 Series Installation Manual55Table 6: Controller BIOS setups for the TLA 700 application (Cont.)Parameter Factory settingSu

Página 70

Appendix B: Upgrades56TLA 700 Series Installation ManualTable 6: Controller BIOS setups for the TLA 700 application (Cont.)Parameter Factory settingSu

Página 71

Appendix B: UpgradesTLA 700 Series Installation Manual576. Press the Enter key again to cause the logic analyzer to automaticallydetermine and set the

Página 72 - Reinstalling Software

Appendix B: Upgrades58TLA 700 Series Installation ManualThe following procedure assumes that the hard disk is already properly for-matted. To reinstal

Página 73 - Reformatting the Hard

Appendix B: UpgradesTLA 700 Series Installation Manual598. After the installation is complete, close all of the dialogs and property sheets.However, k

Página 74 - Set the Display Driver

Appendix B: Upgrades60TLA 700 Series Installation ManualTo reinstall the TLA 700 Series application software, complete the followingsteps:1. Insert th

Página 75 - Diagnostic Software

Appendix B: UpgradesTLA 700 Series Installation Manual61Customizing TLA 700 Series SetupsAfter restoring all of the user and application files, you mu

Página 76

Appendix B: Upgrades62TLA 700 Series Installation ManualThe following steps are only necessary if your logic analyzer uses an externalmonitor. The fol

Página 77 - QAPlus Online Manual

Appendix B: UpgradesTLA 700 Series Installation Manual634. Click OK. After the new settings are in effect, click Yes to keep the newsettings.5. Leave

Página 78 - Adjust the Refresh Rate

Table of ContentsivTLA 700 Series Installation Manual

Página 79 - Utilities

Appendix B: Upgrades64TLA 700 Series Installation ManualThe following virtual memory settings ensure optimal performance of theTLA 700 Series applicat

Página 80 - Enable 32-Bit Support for

TLA 700 Series Installation Manual65Appendix C: Power Cord and Line Fuse Requirements forthe Benchtop MainframeThe benchtop mainframe comes with two p

Página 81

Appendix C: Power Cord and Line Fuse Requirements for the Benchtop Mainframe66TLA 700 Series Installation ManualFor power usage in the nonshaded regio

Página 82

TLA 700 Series Installation Manual vGeneral Safety SummaryReview the following safety precautions to avoid injury and prevent damage tothis product or

Comentários a estes Manuais

Sem comentários