The APPL Window
3-140
AWG610 Arbitrary Waveform Generator User Manual
Table 3-40: Network parameters (cont.)
Standard ClockSamples/
bit
Bit rateLine code
D2 NRZ 143.1800 Mbps 1 143.180 MS/s
D1 NRZ 270.0000 Mbps 1 270.000 MS/s
The network test reading waveform is generated based on the input data, isolated
pulse, and superpose parameters. To generate a waveform, press the Execute side
button.
The clock frequency is the same as the bit rate is set in the Marker 1. When the
sample rate is 1, the clock frequency that is half the bit rate is set in Marker 1.
The input data is set in Marker 2.
. The clock attribute of a generated waveform is the one defined in the
standard.
You can save the generated waveform to a file. If the waveform length does not
satisfy the instrument waveform file length conventions, the instrument repeats
the data several times and regenerates the waveform to create a valid file.
Generating Waveform
Saving to File