Tektronix DPO4000 Manual do Utilizador Página 318

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 585
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 317
Commands Listed in Alphabetical Order
POWer:SWLoss
:TOFF:POWER:MAX? (Query Only)
Returns the maximum Toff power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:TOFF:POWER:M AX?
Examples
POWER:SWLOSS:TOFF:POWER:M AX? might return
:POWER:SWLOSS:TON:POWER:M AX 1 indicating that the maximum Toff power
switching loss calculation is set to 1 W.
POWer:SWLoss:TOFF:POWER:MEAN? (Query Only)
Returns the mean Toff power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:TOFF:POWER:M EAN?
Examples
POWER:SWLOSS:TOFF:POWER:M EAN? might return
:POWER:SWLOSS:TON:POWER:M EAN 1 indicating that the mean Toff power
switching loss calculation is set to 1 W.
POWer:SWLoss:TO FF:POWER:MIN? (Query Only)
Returns the minimum Toff power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:TOFF:POWER:M IN?