Commands Listed in Alphabetical Order
TRIGGER:A:BUS
:B1:FLEXRAY:CYCLECOUNT:HIVAL UE?
might return
TRIGGER:A:BUS:B1:FLEXRAY:C YCLECOUNT:HIVALUE "XXXXXX " indicating
the cycle count high value is don’t care.
TRIGger:A:B
US:B<x>:FLEXray:CYCLEcount:QUALier
Sets or returns the FLEXRAY cycle count qualier.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray :CYCLEcount:QUALifier
{LESSThan|MOREThan|EQUal|U NEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
TRIGger:A:BUS:B<x>:FLEXray :CYCLEcount:QUALifier?
Arguments
LESSThan sets the FLEXRAY cycle count qualier to less than.
MOREThan sets the FLEXRAY cycle count qualier to more than.
EQUal sets the FLEXRAY cycle count qualier to equal.
UNEQual sets the FLEXRAY cycle count qualier to not equal.
LESSEQual sets the FLEXRAY cycle count qualier to less than or equal.
MOREEQual sets the FLEXRAY cycle count qualier to greater than or equal.
INrange sets the FLEXRAY cycle count qualier to in range.
OUTrange sets the FLEXRAY cycle count qualier to out of range.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:C YCLECOUNT:QUALIFIER LESST HAN sets the
cycle count qualier to LESSTHAN.
TRIGGER:A:BUS:B1:FLEXRAY:C YCLECOUNT:QUALIFIER? might return
TRIGGER:A:BUS:B1:FLEXRAY:C YCLECOUNT:QUALIFIER EQUAL indicating
that the cycle count qualier is set to EQUAL.
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue
Sets or returns the binary data string to be used for FLEXRAY cycle count low
value.
Group
Trigger
MSO4000 and DPO4000 Series Programmer Manual 2-403