Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<1-4>:AUDio:DATa:QUALier
Sets or returns the trigger data qualier for the AU DIO bus.
Conditions
This command requires DPO4AUDIO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:QUALifier
{LESSThan|MOREThan|EQUal| UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:QUALifier?
Arguments
LESSThan sets the Audio data qualier to less than.
MOREThan sets the Audio data qualier to greater than.
EQUal sets the Audio data qualier to equa l.
UNEQual sets the Audio data qualier to not equal.
LESSEQual sets the Audio d ata qualier to less than or equal.
MOREEQual sets the Audio data qualier to greater than or equal.
INrange sets the Audio data qualier to in range.
OUTrange sets the Audio data qualier to out of range.
TRIGger:A:BUS:B<1-4>:AUDio:DATa:VALue
Sets or returns the trigger data lower word for the AUDIO bus.
Conditions
This command requires DPO4AUDIO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:VALue <String>
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:VALue?
Arguments
<String> species the trigger data lower word.